CHMiX
Specialty Chemicals
Manufacturing Intelligence
STE Chemicals HYDROGENATOR TT-6D4-01

SPC Analytics

Statistical process control computed live from FactoryTalk DataMosaix — individuals chart, process capability, and Western Electric rule checks. Last 24h.

Cp
1.23
Cpk
1.14
Mean (x̄)
174.351
Sigma (σ)
9.117
In Control
96.9%
Violations
18
Individuals Control Chart — TT-6D4-01 (°C)
Mean 174.351 UCL/LCL 201.701 / 147.001 Spec USL/LSL 205.6 / 138.4
Distribution
Rule Violations
Timestamp Value Rule
04-Sep 11:14 183.14 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 11:19 186.83 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 14:49 203.38 Rule 1 — beyond 3σ
04-Sep 15:29 176.92 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 15:34 190.64 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 15:39 177.13 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 15:44 185.60 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 23:04 144.02 Rule 1 — beyond 3σ
05-Sep 01:39 165.06 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 01:44 164.34 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 01:49 167.23 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 01:54 171.63 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 01:59 169.71 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 02:04 167.59 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 02:09 166.06 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 04:14 162.37 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 04:19 160.15 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 04:24 167.32 Rule 2 — 9 consecutive points on one side of the mean