Statistical process control computed live from FactoryTalk DataMosaix — individuals chart, process capability, and Western Electric rule checks. Last 24h.

Cp
0.95
Cpk
0.94
Mean (x̄)
9.72
Sigma (σ)
3.391
In Control
96.4%
Violations
21
Individuals Control Chart — PT-6R1-01 (Bar)
Mean 9.72 UCL/LCL 19.893 / -0.452 Spec USL/LSL 19.3 / 0.0
Distribution
Rule Violations
Timestamp Value Rule
04-Sep 23:19 5.94 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 23:24 5.53 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 10:54 11.71 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 10:59 15.83 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:04 12.07 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:09 13.44 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:14 14.71 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:19 15.59 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:24 9.75 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:29 19.30 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:34 10.33 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:39 13.11 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:44 13.76 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 11:49 13.48 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 13:39 11.66 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 16:34 13.19 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 16:39 14.62 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 16:44 17.79 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 16:49 9.90 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:24 5.82 Rule 2 — 9 consecutive points on one side of the mean