CHMiX
Specialty Chemicals
Manufacturing Intelligence
STE Chemicals AOS TE-60104

SPC Analytics

Statistical process control computed live from FactoryTalk DataMosaix — individuals chart, process capability, and Western Electric rule checks. Last 24h.

Cp
1.5
Cpk
1.47
Mean (x̄)
39.767
Sigma (σ)
3.343
In Control
97.6%
Violations
14
Individuals Control Chart — TE-60104 (°C)
Mean 39.767 UCL/LCL 49.795 / 29.739 Spec USL/LSL 55.0 / 25.0
Distribution
Rule Violations
Timestamp Value Rule
04-Sep 16:04 43.69 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 21:29 37.53 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 21:34 39.30 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 21:39 39.17 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 21:44 37.49 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 13:29 44.72 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 15:54 42.41 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 15:59 44.68 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:09 35.30 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:14 35.77 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:19 35.69 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:24 34.24 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:29 39.00 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:34 36.43 Rule 2 — 9 consecutive points on one side of the mean