CHMiX
Specialty Chemicals
Manufacturing Intelligence
STE Chemicals AOS TE-30501

SPC Analytics

Statistical process control computed live from FactoryTalk DataMosaix — individuals chart, process capability, and Western Electric rule checks. Last 24h.

Cp
1.55
Cpk
1.24
Mean (x̄)
179.714
Sigma (σ)
10.787
In Control
97.2%
Violations
16
Individuals Control Chart — TE-30501 (°C)
Mean 179.714 UCL/LCL 212.075 / 147.354 Spec USL/LSL 220.0 / 120.0
Distribution
Rule Violations
Timestamp Value Rule
05-Sep 02:44 176.12 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 02:49 171.31 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 02:54 162.41 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 02:59 159.08 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 03:04 174.13 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 03:09 176.36 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 12:09 208.72 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 12:14 187.07 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 12:19 183.58 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 18:44 177.01 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 18:49 170.01 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 23:14 173.67 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 23:19 171.44 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 23:24 157.74 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 02:59 176.49 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 03:24 146.09 Rule 1 — beyond 3σ