SPC Analytics
Statistical process control computed live from FactoryTalk DataMosaix — individuals chart, process capability, and Western Electric rule checks. Last 24h.
Utility
Cp
1.14
Cpk
0.97
Mean (x̄)
4.826
Sigma (σ)
1.035
In Control
98.4%
Violations
9
Individuals Control Chart — LIC-0401 (%)
Mean 4.826
UCL/LCL 7.931 / 1.722
Spec USL/LSL 8.9 / 1.8
Distribution
Rule Violations
| Timestamp | Value | Rule |
|---|---|---|
| 04-Sep 10:49 | 6.00 | Rule 2 — 9 consecutive points on one side of the mean |
| 04-Sep 10:54 | 5.05 | Rule 2 — 9 consecutive points on one side of the mean |
| 04-Sep 13:59 | 4.90 | Rule 2 — 9 consecutive points on one side of the mean |
| 04-Sep 14:04 | 5.90 | Rule 2 — 9 consecutive points on one side of the mean |
| 05-Sep 02:34 | 4.42 | Rule 2 — 9 consecutive points on one side of the mean |
| 05-Sep 05:14 | 4.43 | Rule 2 — 9 consecutive points on one side of the mean |
| 05-Sep 05:19 | 3.97 | Rule 2 — 9 consecutive points on one side of the mean |
| 05-Sep 05:24 | 4.17 | Rule 2 — 9 consecutive points on one side of the mean |
| 05-Sep 08:14 | 5.17 | Rule 2 — 9 consecutive points on one side of the mean |