CHMiX
Specialty Chemicals
Manufacturing Intelligence
STE Chemicals FSP FT-PD1

SPC Analytics

Statistical process control computed live from FactoryTalk DataMosaix — individuals chart, process capability, and Western Electric rule checks. Last 24h.

Cp
1.43
Cpk
1.23
Mean (x̄)
8115.097
Sigma (σ)
85.308
In Control
97.4%
Violations
15
Individuals Control Chart — FT-PD1 (kg/hr)
Mean 8115.097 UCL/LCL 8371.02 / 7859.173 Spec USL/LSL 8534.0 / 7800.0
Distribution
Rule Violations
Timestamp Value Rule
04-Sep 13:04 8134.38 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:09 8187.54 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:14 8182.29 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:19 8150.18 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:24 8147.22 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:29 8148.54 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:34 8210.34 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:39 8217.42 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 13:44 8157.44 Rule 2 — 9 consecutive points on one side of the mean
04-Sep 14:54 8123.79 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 03:29 8103.21 Rule 2 — 9 consecutive points on one side of the mean
05-Sep 16:19 8375.10 Rule 1 — beyond 3σ
06-Sep 02:09 8099.44 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 02:14 7986.81 Rule 2 — 9 consecutive points on one side of the mean
06-Sep 02:19 8080.69 Rule 2 — 9 consecutive points on one side of the mean